specialists in coagulation testing









#M3201: Heparin Antibody - washed-platelet HIPA

COMPONENTS
Name Method Ref Range Units Panic
Value
Frequency Method Description
washed-platelet HIPA HIPA Normal % Positive Daily Quantitative

SPECIMEN REQUIREMENTS
Name Type Volume Aliquot # Temp Container Type Primary/
Alternate
washed platelet-HIPA Serum 1 mL 1 Frozen Red Top

GENERAL INFORMATION
Abbreviations wp-HIPA
Test Frequency Available daily
Alternate Names HAT, HIPA, HIT
CPT Code 86022*2
Notes The washed-platelet Heparin-induced Platelet Activation (HIPA) test is a functional assay that detects clinically significant heparin antibodies. The HIPA has the same published sensitivity and specificity for heparin-associated antibodies as the Serotonin Release Assay (SRA). This test is a modification of the HIPA test described by Greinacher and Warkentin.
 